Dexter T-50 50lb Dryer

Dexter T-50 50lb Dryer

Specifications

SKU: DC0050NC Category:

Description

Capacity Dry Weight Capacity – lb (kg)             50 (22.7)
  Cylinder Volume – cu ft (L)             15.8 (447.4)
Speed Tumbler Speed – RPM             45
  Motor Size – 60 Hz Model – hp (kW)             1 (0.75)
  Motor Size – 50 Hz Model – hp (kW)             0.75 (0.56)
Airflow 60 Hz Model – cfm (M3/min)             910 (25.8)
  50 Hz Model – cfm (M3/min)             760 (21.5)
Dimensions Cabinet Height – in (cm)             72 1/4 (183.5)
                   
  Cabinet Width – in (cm)             34 1/2 (87.6)
  Cabinet Depth – in (cm)             48 (121.9)
  Door Opening – in (cm)             25 5/8 (65.1)
  Floor to Door Bottom – in (cm)             27 1/4 (69.2)
  Cylinder Diameter – in (cm)             32 1/2 (82.6)
  Cylinder Depth – in (cm)             33 (83.8)
  Lint Screen Area – sq in (sq cm)             708 (4568)
                   
Weight Net Weight – lbs (kg)             540 (244.9)
                   
Shipping Shipping Weight – lbs (kg)             590 (267.6)
                   
  Shipping Height – in (cm)             77 1/4 (196.2)
  Shipping Width – in (cm)             36 (91.4)
  Shipping Depth – in (cm)             51 1/2 (130.8)
                   
Gas (Gas Models Only) Gas Supply Connection – in (mm)             1/2 (12.7)
                   
  Natural Gas Supply (Water Column) – in (cm)             5-8 (12.7-20.3)
  LP Gas Supply (Water Column) – in (cm)             11 1/2-13 1/2 (29.2-34.3)
  Gas Usage – 60Hz Model – BTU/hr (kW)             145,000 (42.5)
  Gas Usage – 50Hz Model – BTU/hr (kW)             120,000 (35.2)
Electrical Gas Models   Volts / Hz / Phase / Wiring         Circuit Breaker Amps / Running Amps / Wire Size / Reversing Availability  
  -10   120 / 60 / 1 / 2 wire + ground         15 / 9.6 / #12 / Non-Reversing  
  -39   230 / 50 / 1 / 2 wire + ground         10 / 5.1 / 2.1 mm2 / Non-Reversing  
  -59   230 / 50 / 1 / 2 wire + ground         10 / 5.1 / 2.1 mm2 / Non-Reversing  
  Electric Models   kW / Volts / Hz / Phase / Wiring         Circuit Breaker Amps / Running Amps / Wire Size / Reversing Availability  
                   
  -79   24 / 400 / 50 / 3 / 4 wire + ground         50 / 45 / 13.3 mm2 / Non-Reversing  
Installation Minimum Clearance Between Machines – in (cm)             0 0
  Minimum Clearance Behind Machines – in (cm)             18 (45.7)
  Make-Up Air Required – sq ft (sq cm)             1.25 (1161)
  Exhaust Size – in (cm)             8 (20.3)
  Max. Exhaust Back Pressure (Water Column) – in (mm)             0.3 (7.6)
  Recommended Exhaust Length – ft (m) & 2 elbows             14 (4.3)